Technical parameter:
¡¡
1.
Wavelength range: 400
nm-800 nm.
2.
Interference filter:
8-hole filter wheel, factory standard
410nm, 451nm, 490nm, 630nm four filters.
Install up to 8 interference filters,
testing needs to adapt to a variety of
projects.
3.
Test channel: the
9-channel optical system, in which 8 of
48 light sources are used to optical
signal detection. In addition an optical
light source for calibration, the system
of compensation as the light source and
light work of the monitoring.
4.
Light source: Halogen
lamp
5.
test range: 0¡«4A
6.
resolution ratio 0£®001A
7.
Accuracy: ¡À1%(0¡«2A)
8.
linear error: ¡À0.1%(0¡«2A)
9.
Repeatability: ¡À0.005A(0¡«2A)
10.
Stability: ¡Ü0.005A/hour
11.
System Interface: RS-232/
USB. It can connect pc with RS232 or
USB, and control of the machine.
12.
Storage: Large capacity
memory, can store 8000 sets of
measurements raw data.
13.
Peripherals: Built-in
embedded miniature thermal printer,
large-screen LCD display.
14.
Sample can be sample
introduction, and automatic shake.
15.
With single /
dual-wavelength two measurement modes,
users can select the appropriate
measurement mode
16.
Instrument with
qualitative and quantitative analysis
function, the report can be exported raw
absorbance and concentration data
reports, the results of qualitative
analysis to determine the yin and yang
of the report.
17.
The default configuration
of many kinds of commonly used drug
residue testing program of qualitative
and quantitative analysis of detection
methods, the user can either ELISA
analysis according to a common mode of
the instrument set, you can choose the
default configuration for the instrument
operation, simplifying the user's steps
. Users can save the current settings
the default settings for the project,
next time do not reset the equipment
transferred to work.
18.
Provide car power
connector and suitable for vehicle or
mobile laboratory.
¡¡
|