¡¡

¡¡

Others

 

Y-48-channel Rapid Animal Disease Diagnostic Unit

¡¡

¡¡

   

Product introduction

¡¡

Type No.: HWVD-48YB

¡¡

Application£º

It is widely used in rapid diagnosis of animal diseases such as PRRS virus, swine fever virus, porcine pseudorabies virus, porcine pseudorabies virus gE protein, porcine circovirus, porcine encephalitis virus, 3ABC protein pig foot and mouth disease, swine foot and mouth disease virus IgG, porcine parvovirus, chicken bird flu, bluetongue, white spot syndrome, contagious bovine pleuropneumonia, rinderpest, sheep pox and goat pox and other quantitative rapid detection, and can be connected with diagnosis of disease systems networking.

¡¡

 

Technical parameter:

¡¡

1.    Wavelength range: 400 nm-800 nm.

2.    Interference filter: 8-hole filter wheel, factory standard 410nm, 451nm, 490nm, 630nm four filters. Install up to 8 interference filters, testing needs to adapt to a variety of projects.

3.    Test channel: the 9-channel optical system, in which 8 of 48 light sources are used to optical signal detection. In addition an optical light source for calibration, the system of compensation as the light source and light work of the monitoring.

4.    Light source: Halogen lamp

5.    test range: 0¡«4A

6.    resolution ratio 0£®001A

7.    Accuracy: ¡À1%(0¡«2A)

8.    linear error: ¡À0.1%(0¡«2A)

9.    Repeatability: ¡À0.005A(0¡«2A)

10. Stability: ¡Ü0.005A/hour

11. System Interface: RS-232/ USB. It can connect pc with RS232 or USB, and control of the machine.

12. Storage: Large capacity memory, can store 8000 sets of measurements raw data.

13. Peripherals: Built-in embedded miniature thermal printer, large-screen LCD display.

14. Sample can be sample introduction, and automatic shake.

15. With single / dual-wavelength two measurement modes, users can select the appropriate measurement mode

16. Instrument with qualitative and quantitative analysis function, the report can be exported raw absorbance and concentration data reports, the results of qualitative analysis to determine the yin and yang of the report.

17. The default configuration of many kinds of commonly used drug residue testing program of qualitative and quantitative analysis of detection methods, the user can either ELISA analysis according to a common mode of the instrument set, you can choose the default configuration for the instrument operation, simplifying the user's steps . Users can save the current settings the default settings for the project, next time do not reset the equipment transferred to work.

18. Provide car power connector and suitable for vehicle or mobile laboratory.

¡¡

¡¡


IT PROMOTING: BEIJING YIYUAN IT LTD

IN&EXPORT: BEIJING YIYUAN ECONOMIC TRADE LTD

WEBSITE: machine.mycotrade.com

E-MAIL: sales@mycotrade.com