Y-Rapid diagnosis of the disease, antibiotics and veterinary drugs fast tester

¡¡

¡¡

   

Product introduction

¡¡

1.  Optical system

1.1 Wavelength range: 400-800nm

1.2 Interference filter: 8-hole filter wheel, factory standard 405nm, 451nm, 490nm, 630nm four filters. Install up to 8 interference filters, testing needs to adapt to a variety of projects.

1.3 Test channel: the 9-channel optical system, in which 8 of 96 light sources are used to optical signal detection. In addition an optical light source for calibration, the system of compensation as the light source and light work of the monitoring.

1.4 Light sources: halogen tungsten lamp

¡¡

2.  HWVD series technical parameter

 2.1 test range: 0¡«4A

 2.2 resolution ratio 0£®001A

 2.3 Accuracy: ¡À1%(0¡«2A)

 2.4 linear error: ¡À0.1%(0¡«2A)

 2.5 Repeatability: ¡À0.005A(0¡«2A)

 2.6 Stability: ¡Ü0.005A/hour

 2.7 System Interface: RS-232/ USB. It can connect pc with RS232 or USB, and control of the machine.

 2.8 Storage: Large capacity memory, can store 8000 sets of measurements raw data.

 2.9 Peripherals: Built-in embedded miniature thermal printer, large-screen LCD display.

¡¡

3.  Software system functions:

 3.1 with single / dual-wavelength two measurement modes, users can select the appropriate measurement mode

 3.2 Instrument with qualitative and quantitative analysis function, the report can be exported raw absorbance and concentration data reports, the results of qualitative analysis to determine the yin and yang of the report.

 3.3 The default configuration of many kinds of commonly used drug residue testing program of qualitative and quantitative analysis of detection methods, the user can either ELISA analysis according to a common mode of the instrument set, you can choose the default configuration for the instrument operation, simplifying the user's steps . Users can save the current settings the default settings for the project, next time do not reset the equipment transferred to work.

¡¡

4.  Apparatus under normal operating conditions

 4.1 Ambient temperature: 5¡æ ¡«+32¡æ£»

 4.2 Relative humidity (RH): ¡Ü85%£»

 4.3 Atmospheric pressure: 860hPa ¡« 1060hPa£»

 4.4 Keep away from strong electromagnetic interference sources, and avoid direct exposure to bright light.

 4.5 Mains input: 100VAC ¡« 230VAC 50Hz¡À1Hz or 60 ¡À1Hz£¬suitable for 110v and 220v power-supply system.

¡¡

¡¡