Drug
residues detector
¡¡
Y48
channels veterinary drugs residues
tester
¡¡
Product
introduction
Product name: 48
channels veterinary drugs residues
tester
Type No.:
HWVD-48SY
Application
Y48 channels veterinary drugs residues
tester could test the residues of
ractopamine, aflatoxin B1, clenbuterol,
afatoxin total volume,
Avermectins, amitraz,
Amoxicillin,
Ampicillin, amprolium,
Aprymycin,
Arsanilic acid, Avermectins,
Azamethiphos,
Azaperone,
bacitracin,
ceftiofur,
Clavulanate,
Clopidol. It also can be connected with
the food safety controlling system.
¡¡
Technical parameter:
¡¡
1.
Light path system
1.
one piece interfering
glass filter: 8 holes filter turntable,
four filter of factory standard by 410nm£¬451nm£¬490nm£¬630nm.
It can install 8 interference filters,
to adapt to a variety of detection
project need.
2.
Test channel: 9 channels
light path system,
3. Light
source: halogen light
¡¡
2. Technical
parameter
1. Optional
choose 1-48 channels to test at the same
time.
2. Wave
length scope: 300-800nm
3. Test
scope: 0¡«4A
4. Resolution
ratio:
0£®001A
5. Accuracy
rating: ¡À1%(0¡«2A)
6. Linear
error: ¡À0.1%(0¡«2A)
7. Repeatability:
¡À0.005A(0¡«2A)
8. Stability:
¡Ü0.005A/H
9. System
Interface: RS-232/USB, use RS232 or USB
interface to connecting with PC, and
controlling the tester working.
10.
Storage: large storage,
can store 8000 set testing source data
11.
Peripheral: Built-in
embedded miniature thermal printers, big
screen LCD display.
12.
The sample can be
automatically injected sample,
automatically vibration wave.
¡¡
3. Function
of software system:
1. With
single/double wavelengths two
measurement model function, the user can
choose the proper measurement model
according to the need.
2. The
instrument has the qualitative and
quantitative analysis function, can
output the original absorbency report,
concentration data report, qualitative
analysis of the positive result
determination report.
3. The
default configuration multiple commonly
used multiple drug residue detection
project qualitative and quantitative
analysis, the user can test method
according to the general ELISA analysis
method of the instrument set work mode,
also can choose the default
configuration instrument operation, the
simplified user operation step. Users
can set for the current preservation
purpose, and the next time a default
Settings need not to set instruments way
of working.
¡¡
4. The
tester work normally.
1. Temperature:
5¡æ
¡«+32¡æ
2.
Humidity: ¡Ü85%
3.
Atmosphere: 860hPa
¡«
1060hPa
4. Far
from strong interference sources, avoid
the electromagnetic field and directly
light by the strong light. |