Incubator
Mould Cultivation Cabinet
Uses:
This equipment is widely used in environmental
protection, epidemic prevention, workshop,
chemical pharmaceutical, drug test, fishery and
other areas of research experiment and
production department. It is the specialized
thermostatic equipment for water analysis, BOD
test, and bacteria, moulds and microorganism
cultivation and storage, as well as plant
cultivation and seed-breeding test.
Characteristics of standard incubator:
1. Stainless steel inner chamber; with the
semicircular arcs at corners for easy cleaning
, convenient to clean, space between shelves is
adjustable.
2. Micro-computer control system ensures precise
and reliable temperature control; LCD enables
multiple groups of data to be displayed at a
time; ultraviolet germicidal lamp.
3. Independent humidification, sterilization and
temperature limit system with function of
over-temperature alarm and auto-power-cut-off.
4. Test hole of ¡é52mm at left side of container.
5. Double airtight door structure.
6. Fluoride-free refrigeration.
Characteristics of functional incubator:
1.Intelligent programmed temperature and
humidity control system with program of 30
sections ensure timing,repeated or multistep
running of temperature and humidity.
2.No freezing thanks to intelligent
refrigeration and defrosting system.
3.Function of auto running, auto stopping and
timing running, as well as parameter memorizing,
power reset recovering and temperature display
revising.
4.Watch timer and independent temperature safety
device, which auto breaks off when over
temperature limit.
5.Function of self-diagnosis, sensor failure
alarm and over temperature protection.
Optional accessories:
a.Printer (desktop).
b.Supplementare oxygen,nitrogen interface.
c.RS485 interface for communication software
connection.Main
Parameters£º
Model |
Standard form |
CTNYYMJX-70B¢ó |
CTNYYMJX-150B¢ó |
CTNYYMJX-250B¢ó |
Functional form |
CTNYYMJX-70BX |
CTNYYMJX-150BX |
CTNYYMJX-250BX |
voltage |
220V/50Hz |
Tem.Range (¡æ) |
With Humidification£º10¡«65 Without
Humidification£º0¡«65¡æ |
Tem.Resolution Ratio (¡æ) |
0.1¡æ |
Tem. volatility (¡æ) |
High Temperature0.5¡æ Low
Temperature¡À1¡æ |
Tem. uniformity (¡æ) |
¡À1¡æ |
Humidity range |
60-90%RH |
Humidity error |
5-8%RH |
Power (w) |
500 |
800 |
1200 |
Coolant |
R134a |
Amebient tem. (¡æ) |
5-30¡æ |
Inner Champer Size (mm) |
420¡Á350¡Á500 |
500¡Á400¡Á750 |
500¡Á500¡Á950 |
Exterior Size (mm) |
570¡Á560¡Á1200 |
640¡Á620¡Á1270 |
660¡Á700¡Á1470 |
Packing Size (mm) |
730¡Á720¡Á1170 |
820¡Á760¡Á1430 |
880¡Á825¡Á1645 |
N.W. (Kg) |
59.5 |
68.5 |
72 |
G.W.(Kg) |
86 |
98 |
116 |
Timing |
1-9999min |
¡¡ |
|