Uses :
With precise temperature and humidity control
system, this equipment provides variety of
environmental simulate conditions that
industrial research and biological test need. It
is used in medicine, textile and food production
experiment, as well as in product stability, raw
material, packing and lifetime test.
Characteristics of standard form incubator:
1.Mirror finished stainless steel inner chamber;
with the semicircular arcs at corners for easy
cleaning, convenient to clean; space between
shelves is adjustable.
2.Micro-computer temperature and humidity
controller with program of 330 sections to
ensure timing, repeated or multistep running of
temperature and humidity; Function of over
temperature protection and timing; LCD enables
multiple groups of data to be displayed at a
time.
3.Test hole of ¡é52mm at left side of chamber.
4.Brand compressor, fluoride-free refrigeration.
5.Double airtight door, which is convenient to
on/off; with light in inner chamber for
convenient viewing (The lamp can be replaced
with ultraviolet ray sterilizing lamp as user¡¯s
need).
6.Equipped with ultrasonic humidifier and
intelligent atomizer.
Characteristics of functional form incubator:
1.No freezing in inner chamber thanks to
intelligent refrigeration and defrosting system.
2.Function of auto running, auto stopping and
timing running, as well as parameter memorizing,
power reset recovering and temperature display
revising.
3.Watch timer and independent temperature safety
device; auto alarm and auto break off when over
temperature limit
to ensure experiment runs safely and no accident
would happen.
4.Function of self-diagnosis, sensor failure
alarm and over temperature protection.
Optional accessories:
a.Printer (desktop).
b.Supplementare oxygen,nitrogen interface.
c.RS485 interface for communication software
connection. Main
parameters£º ¡¡
Model |
Standard form |
CTNYYHWS-70B |
CTNYYHWS-150B |
CTNYYHWS-250B |
Functional form |
CTNYYHWS-70BX |
CTNYYHWS-150BX |
CTNYYHWS-250BX |
voltage |
220V/50Hz |
Tem.Range (¡æ) |
Humidification: 10~65¡æ No
humidification: 0~65¡æ |
Tem.Motion (¡æ) |
High Temperature0.5¡æ Low
Temperature¡À1¡æ |
Humidity Range |
45%-90%RH |
Ambient tem. (¡æ) |
5-35¡æ |
Humidity error |
¡À5%-8%RH |
Power(W) |
500 |
800 |
1200 |
Inner Champer Size (mm) |
420¡Á350¡Á500 |
500¡Á400¡Á750 |
500¡Á500¡Á950 |
Exterior Size (mm) |
570¡Á590¡Á1020 |
645¡Á640¡Á1270 |
660¡Á740¡Á1470 |
Packing Size (mm) |
730¡Á720¡Á1200 |
800¡Á780¡Á1440 |
880¡Á800¡Á1630 |
Load per rack |
15kg 2pcs
for standard configuration |
N.W. (Kg) |
69 |
86 |
100 |
G.W. (Kg) |
92 |
114 |
139 |
¡¡ |