Y-Malachite green speed test reagent
Product Introduction
Application
A. It is widely used to detect various
types of aquarium, ponds and other
water, whether it contains malachite
green ingredients. B. Speed
test
agents malachite green box (Ⅰ)
is only used for preliminary screening
of suspected samples using the malachite
green; C, malachite green speed test
agent box (Ⅱ)
to confirm whether the samples contain
malachite green component.
Test principle
Enriching column can concentrate and
enrich hundred times of the Malachite
green content in the breed aquatics
water, after the malachite green
enriched by the enriching column, the
adsorption in the column will be some
obvious green ribbon. Then the malachite
eluted by the eluant again. If the
eluant appears green that can be used
malachite green. If compare the eluant
with the malachite standard sample to be
characterized, to confirm whether the
use of malachite green.
Specification: 10 times.
Storage: normal temperature, avoid from
sunlight.
Packing: 1. malachite green enrichment
column: 10 branches, 2. eluent: 2
bottles, 3. the control solution of
malachite green: 1 bottle, 4. ear
cleaning balls: 1 (provide for oneself),
5. Transfusion system: 4 pay.
Period validity: 6 months.
Usage
1. Sampling: First close the transfusion
device at the lower end of the
transfusion pipe flow controller, using
25ml or 100ml syringe sampling and want
to check the fluid directly from the
infusion bag ( tank ) sample adding
holes to join. When the enriching column
enrichment of 100ml samples can be
detected malachite green minimum
concentration is 3UG / L, 300ml
enrichment can be detected malachite
green the lowest concentration of 1 ug /
L. After the sample is loaded into the
transfusion bag (tank) hanging on a nail
or hook.
2. Enrichment: (1) Exhaust: According to
the experimental setup, first slowly
open the infusion flow rate controller,
so that the liquid from the drainage
guide Tube out until the bottom of the
liquid outflow from the catheter side by
side under a clean air-water separator
tube in the bubble (the liquid should be
filled with gas-water separator below
the catheter and the catheter should be
absolutely no air bubbles), quick adjust
water flow rate controller is switched
off, rapidly the enrichment column big
mouth on the end of the receiving
drainage catheter. Accordance with the
"speed test case for use of malachite
green," photos two of the "Exhaust" port
up under the enrichment column, and then
open the flow controller, so that slowly
filled with liquid enrichment column,
and the discharge column gas. (2) Such
as "malachite green-speed measuring box
for use" as shown in photo one, put down
the enrichment column, under the port,
so that the liquid Flow through the
enrichment column for enrichment.
Control the flow rate of about 60 drops
per minute.
3. Elution: flow to be completely liquid
sample enrichment column, the enrichment
column off; wash the ear with the ball
towards the column from the column
packing pressure port blowing, the water
column to catch a clean and dry as
possible. Enrichment column from the
column after drying by adding 1 ml
eluant port and let the liquid naturally
shed, collecting eluate in the control
vials.
4. Results of observation: If cylinder
filler layer that was green and down as
the eluent, the preliminary view that
may contain malachite green, otherwise
it is negative. Or collection of the
eluate can be initially considered for
the green malachite green may be.
Main technical parameters:
Flow through the enrichment column
sample enrichment time to detect the
lower limit of detection
100ml 25-30min
3.0 ug/L(3.0ppb)
300ml 75 - 90min
1.0 ug/L(1.0ppb)
Announcements
1. If the turbidity test samples should
be filtered before use.
2. On-site detection of positive samples
should be used to test reagents
malachite green-speed box (Ⅱ)
to confirm or high performance liquid
chromatography.
3. The use of malachite green standard
working solution: This kit provides the
standard working solution available for
beginners training. Standard working
solution concentration is 75ug/ml,
before using to draw 50mL water to
adding a drop of standard working
solution that has been diluted to
0.075ug/mL of malachite green solution.
Take 15ml diluents through the
enrichment column, column packing
enriched significantly in the green.